A method for measuring high viscosity in surface tension

更新時間:2017-04-20 10:32:42點擊次數:3018次字號:T|T
This method is applied in the measurement of the viscosity of more than 500CP.S liquid, measured for more than 5 minutes, the measured value will reach a stable (not including the liquid itself with the nature of the change) such as glycerol, viscose and
A method for testing high viscosity liquids
This method is applied in the measurement of the viscosity of more than 500CP.S liquid, measured for more than 5 minutes, the measured value will reach a stable (not including the liquid itself with the nature of the change) such as glycerol, viscose and so on.
Method 1, manual mode:
(1) hang the platinum plate and return to zero;
(2) QBZY surface tension meter "manual / automatic" to the manual state. That is, the indicator light does not light;
(3) Follow the steps below to raise the sample stage to the platinum plate:
A Press the "Up" button to raise the sample.
B Press the "Stop" button when the platinum plate comes into contact with the sample surface. Stop the rise of the sample stage. After the stop, the platinum plate should be exposed to the sample surface, and the LCD screen shows the surface tension value is negative. Note that this exposure to the height of the white gold plate into the sample depth of about 1mm or so (in fact because of the high viscosity of the sample, the white gold plate began to contact the sample can not really insert but the sample hold up).
(4) Remove the white gold plate and wet the 5mm height (not too high, and if the display value is more than 5mN / m, please scratch the white surface of the sample until the display value is less than 5mN / m)
(5) to re-hang the platinum plate, this time the sample will come into contact with the platinum plate, and the phenomenon of surface tension, the completion of the wet process.
(6) and so relatively stable when reading readings.

Method 2, automatic operation:
We recommend that customers use this method to operate, but if the time requirements are higher, please test according to the third method.
(1) hang the platinum plate and return to zero;
(2) Remove the platinum plate and wet the 5mm height;
(3) the use of tissue paper will be attached to the white gold plate on the liquid wipe some;
(4) re-hang the platinum board, then the display value will be greater than 0, please do not return to zero, if the display value is greater than 5mN / m, please wipe some;
(5) press the "up" button to test, remember the stability value.
(編輯:HengZheng)
0 條評論
不想登錄?直接點擊發布即可作為游客留言。

新聞中心列表

公司新聞
行業資訊

新聞推薦

電子天平使用應具備的基本知識

電子密度天平計量檢定項目

在日常的周期檢定和常規的產品質量檢查中,一般需要檢定以下幾項內容...

JA系列電子天平選購應該注意哪...

JA系列電子天平對操作人員的兼容性和對操作環境的耐受能力。

如何正確使用FA系列電子天平?

準備將FA系列電子天平放在穩定的工作臺上,避免振動,氣流、陽光直...

FA系列電子天平使用的注意事項

電子天平如何測量固體密度

鹵素水分測定儀操作過程

聯系我們

地址:江蘇省常州市鐘樓區龍城大道2188號新閘科技園

聯系人:查小姐
郵編:213000
電話:0519-83263587
傳真:0519-83268313
網址:http://www.czhzyq.com/

聯系我們
地址:常州市鐘樓區龍城大道2188號新閘科技園10棟313
聯系人:查小姐
電話:0519-83263587
傳真:0519-83268313
網址:http://www.xfdxdl.cn
關注衡正
Copyright ? 2017 - 2024 All Rights Reserved 常州市衡正電子儀器有限公司 版權所有  蘇ICP備17024635號 技術支持:冉冉科技 網站地圖